beautypg.com

Chapter 3 installing the level 10r storage system – Grass Valley K2 Storage System Instruction Manual v.3.3 User Manual

Page 138

background image

138

K2 Storage System Instruction Manual

June 25, 2009

Chapter 3 Installing the Level 10R Storage System

K2 Media Server failover with Control team failover behavior

If the following system component fails to respond to system communication:

• The “A” GigE switch

Then the following failover behavior occurs:

1. The media file system (SNFS) and media database (SQL) on K2 Media Server “A”

fail over and K2 Media Server “B” becomes the active media file system/database
server.

2. All K2 Media Clients drop communication on the “A” media port and begin using

the “B” media port, finding a path through GigE switch “B” to K2 Media Server
“B”. All K2 Media Clients use an iSCSI adapter (TOE) on the “B” K2 Media
Server to provide access to the Fibre Channel connected RAID storage.

3. For all K2 Media Clients, communication fails on the control port, so the control

team fails over and communication begins on the other control port.

4. For all K2 Media Clients, control communication finds a path through GigE switch

“B” to K2 Media Server “B”.

K2 RAID

K2 Media
Servers

K2 clients

Gigabit
Ethernet
switches

A

A

B

B

Fibre Channel
connections

Control

Media

Control

Media

Control

FTP

Media

Media

!

K2

S A S S T O R A G E

!

K2

S D I M E D I A C L I E N T

!

K2

S D I M E D I A C L I E N T

!

K2

S D I M E D I A C L I E N T

!

K2

S D I M E D I A C L I E N T

K2

M E D I A S E R V E R

Control

FTP

Media

Media

K2

M E D I A S E R V E R

ISLs

X

Component
Failure