beautypg.com

Grass Valley K2 Storage System Instruction Manual v.3.3 User Manual

Page 71

background image

June 25, 2009

K2 Storage System Instruction Manual

71

Configuring RAID

b. Leave Full Bind unchecked. Refer to

“About full/background bind” on

page 548

.

c. In the

Bind Type

drop down box, select

RAID 5

or

RAID 6

, as specified by your

system design.

d. In the Available Disks box, select six contiguous disks at the top of the list. (TIP:

Use ‘shift-click’ or ‘control-click’ to select disks.).

e. Click the add (arrow) button to add disks to the Selected Disks list.

NOTE: As an aid in identifying a disk module’s physical location, select it in the
Selected Disks list, then click

Identify Disks.

This causes the disk drive light to flash.

f. Click

OK

to close the Bind dialog box and begin the binding process. The

Progress Report dialog box opens, showing the status of the binding process.