K2 Storage System Instruction Manual

69

Configuring RAID

4. In the Controller Slot Number field enter

0

and then press

Enter

. The settings from

controller 0 are loaded into the Controller Network Settings dialog box and are
available for you to modify.

5. Enter the control network IP address and other network settings.

6. You want SNMP trap messages go to the NetCentral server PC, so for SNMP

Configuration enter the IP address of the NetCentral server PC. You can also enter
IP addresses for other SNMP managers to which you want to send SNMP trap
messages.

7. Click

OK

to save settings and close.

8. In Storage Utility click

View | Refresh

. Continue with the next procedure

“Binding

disk modules”

.

Binding disk modules

Use the following procedure to bind disk modules as required for the Level 10 storage
system.

Also refer to

“About RANKs and LUNs in Storage Utility” in the chapter

Overview

of K2 Storage Tools.

NOTE: Binding destroys all user data on the disks.

1. In the Storage Utility main window, identify bound RANKs and unbound disks by