LWAPP Error Messages
Sensor Messages
Message
Explanation
Recommended Action
LWAPP-3-CDP: Failure sending CDP Update
to Controller. Reason “s”
Could not send access point CDP update to controller
No action is required.
LWAPP-3-CLIENTERRORLOG: “s”
This log message indicates an LWAPP client error event.
The message is logged to help in troubleshooting LWAPP
access point join problems.
No action is required.
LWAPP-3-CLIENTEVENTLOG: “s”
This log message indicates an LWAPP client notification
event. The message is logged to help in troubleshooting
LWAPP access point join problems.
No action is required.
LWAPP-3-UNSUPPORTEDRM: Got unsupported
CCX RM Measurement “s” request “d” from
Controller.
Got unsupported CCX radio managment measurement
request from controller.
No action is required.
LWAPP-5-WRONG_DFS_SLOT: DFS action on
non-DFS radio “d”
DFS action on radio b/g
No action is required.
Message
Explanation
Recommended Action
SENSOR-3-TEMP_CRITICAL: System sensor “d”
has exceeded CRITCAL temperature
thresholds
One of the measured environmental test points exceeds
the extreme threshold.
Correct the specified condition, or the system
can shut itself down as a preventive measure.
Enter the
show environment all
command to help determine if this is due to
temperature or voltage condition. If this is a
critical temperature warning, please verify
that the router fans are operating and that
the room cooling and air-conditioning are
functioning. This condition could cause the
system to fail to operate properly.
SENSOR-3-TEMP_NORMAL: “s” temperature
sensor is now normal
One of the measured environmental test points is under
normal operating temperature.
None required.
SENSOR-3-TEMP_SHUTDOWN: Shuting down the
system because of dangerously HIGH
temperature at sensor “d”.
One of the measured environmental test points exceeds
the operating temperature environment of the router.
Investigate the cause of the high
temperature.
SENSOR-3-TEMP_WARNING: “s” temparature
sensor “d” has exceeded WARNING
temperature thresholds
One of the measured environmental test points exceeds
the warning threshold.
Closely monitor the condition and correct if
possible, by cooling the environment.
SENSOR-3-VOLT_CRITICAL: System sensor “d”
has exceeded CRITCAL voltage thresholds
One of the measured environmental test points exceeds
the extreme voltage threshold.
Correct the specified condition, or the system
can shut itself down as a preventive measure.
Enter the
show environment all
command to help determine if this is due to
voltage condition. This condition could cause
the system to fail to operate properly.
SENSOR-3-VOLT_NORMAL: System sensor
“d”(“d”) is now operating under NORMAL
voltage
One of the measured environmental test points is under
normal operating voltage.
None required.
SENSOR-3-VOLT_WARNING: Voltage monitor
“d”(“d”) has exceeded voltage thresholds
One of the measured voltage test points indicates that
voltage is out of normal range.
Check Power Supplies or contact TAC.