Defining the message severity level – Rockwell Automation 1783-WAPxxx Stratix 5100 Wireless Access Point User Manual User Manual
Page 554

554
Rockwell Automation Publication 1783-UM006A-EN-P - May 2014
Chapter 21
Configuring System Message Logging
Defining the Message Severity Level
You can limit messages displayed to the selected device by specifying the
severity level of the message, that are described in
Table 115 on page 555
.
Specifying a level causes messages at that level and numerically lower levels to
be displayed at the destination.
Beginning in privileged EXEC mode, follow these steps to define the message
severity level:
1. Enter global configuration mode.
configure terminal
2. Limit messages logged to the console.
By default, the console receives debugging messages and numerically lower
levels (see
Table 115 on page 555
).
logging console level
3. Limit messages logged to the terminal lines.
By default, the terminal receives debugging messages and numerically
lower levels (see
Table 115 on page 555
).
logging monitor level
4. Limit messages logged to the syslog servers.
By default, syslog servers receive informational messages and numerically
lower levels (see
Table 115 on page 555
).
For complete syslog server configuration steps, see
logging trap level
5. Return to privileged EXEC mode.
end
6. Verify your entries.
show running-config
or
show logging
7. (Optional) Save your entries in the configuration file.
copy running-config startup-config
• To disable logging to the console, use the
no logging console
global