Configuring System Message Logging
Chapter 21
Configuring the UNIX System Logging Facility
When sending system log messages to an external device, you can cause the
access point to identify its messages as originating from any of the UNIX
syslog facilities.
Beginning in privileged EXEC mode, follow these steps to configure UNIX
system facility message logging:
1. Enter global configuration mode.
configure terminal
2. Log messages to a UNIX syslog server host by entering its IP address.
To build a list of syslog servers that receive logging messages, enter this
command more than once.
logging host
3. Limit messages logged to the syslog servers.
Be default, syslog servers receive informational messages and lower.
logging trap level
See
Table 115 on page 555
for level keywords.
4. Configure the syslog facility.
The default is
local7
.
logging facility facility-type
See
Table 116 on page 560
for facility-type keywords.
5. Return to privileged EXEC mode.
end
6. Verify your entries.
show running-config
7. (Optional) Save your entries in the configuration file.
copy running-config startup-config
• To remove a syslog server, use the
no logging host global
configuration command, and specify the syslog server IP address.
• To disable logging to syslog servers, enter the
no logging trap
global
configuration command.