Rockwell Automation 1783-WAPxxx Stratix 5100 Wireless Access Point User Manual User Manual
Page 531
Rockwell Automation Publication 1783-UM006A-EN-P - May 2014
531
Configuring Repeater and Standby Access Points and Workgroup Bridge Mode
Chapter 20
The table below lists the possible status values of the standby access point.
Configuring a Hot Standby
Access Point by Using CLI
When you set up the standby access point, you must enter the MAC address of
the access point that the standby unit monitors. Record the MAC address of the
monitored access point before you configure the standby access point.
The standby access point also must duplicate several key settings on the
monitored access point. These settings are:
• Primary SSID (as well as additional SSIDs configured on the monitored
access point)
• Default IP Subnet Mask
• Default Gateway
• Data rates
• WEP settings
• Authentication types and authentication servers
Check the monitored access point and record these settings before you set up the
standby access point.
Message Description
IAPP Standby is Disabled
The access point is not configured for standby mode.
IAPP - AP is in standby mode
The access point is in standby mode.
IAPP - AP is operating in active mode
The standby access point has taken over for the monitored access point
and is functioning as a repeater access point.
IAPP - AP is operating in repeater mode
The standby access point has taken over for the monitored access point
and is functioning as a repeater access point.
Standby status: Initializing
The standby access point is initializing link tests with the monitored
access point.
Standby status: Takeover
The standby access point is operating in standby mode and is running link
tests to the monitored access point.
Standby status: Stopped
Standby mode has been stopped by a configuration command.
Standby status: Ethernet Linktest Failed
An Ethernet link test failed from the standby access point to the
monitored access point.
Standby status: Radio Linktest Failed
A radio link test failed from the standby access point to the monitored
access point.
Standby status: Standby Error
An undefined error occurred.
Standby State: Init
The standby access point is initializing link tests with the monitored
access point.
Standby State: Running
The standby access point is operating in standby mode and is running link
tests to the monitored access point.
Standby State: Stopped
Standby mode has been stopped by a configuration command.
Standby State: Not Running
The access point is not in standby mode.
IMPORTANT
Wireless client devices associated to the standby access point lose their
connections during the hot standby setup process.