Displaying the radius configuration, Radius attributes sent by the access point – Rockwell Automation 1783-WAPxxx Stratix 5100 Wireless Access Point User Manual User Manual
Page 428

428
Rockwell Automation Publication 1783-UM006A-EN-P - May 2014
Chapter 14
Configuring RADIUS and TACACS+ Servers
This example shows how to configure the WISPr location-name attribute:
ap# snmp-server location
ACMEWISP,Gate_14_Terminal_C_of_Newark_Airport
This example shows how to configure the ISO and ITU location codes on the
access point:
ap# dot11 location isocc us cc 1 ac 408
This example shows how the access point adds the SSID used by the client device
and formats the location-ID string:
isocc=us,cc=1,ac=408,network=ACMEWISP_NewarkAirport
Displaying the RADIUS Configuration
To display the RADIUS configuration, use the
show running-config
privileged EXEC command.
RADIUS Attributes Sent by the Access Point
Table 99 on page 428
identify the attributes sent
by an access point to a client in access-request, access-accept, and accounting-
request packets.
TIP
When DNS is configured on the access point, the
show running-
config
a server’s IP address can appear instead of its name.
TIP
You can configure the access point to include in its RADIUS accounting and
authentication requests attributes recommended by the Wi-Fi Alliance’s WISPr
Best Current Practices for Wireless Internet Service Provider (WISP) Roaming
document.
See
Configuring WISPr RADIUS Attributes on page 426
for instructions.
Table 99 - Attributes Sent in Access-Request Packets
Attribute ID
Description
1
User-Name
4
NAS-IP-Address
5
NAS-Port
12
Framed-MTU
30
Called-Station-ID (MAC address)
31
Calling-Station-ID (MAC address)
32
NAS-Identifier
(1)