Recording to a New Cue List

When recording cues, cue list 1 is initially used as the default cue list. Cue list 1 is displayed with
only the cue number. It does not have a lead cue list number or a “/”. To record to another cue list,
that list must first be specified. Cues will then be recorded to that cue list until another list is
specified, or until the selected cue is changed in live.

You may record up to 99 cue lists in an Eos show file.

The cue list that you are storing to is always determined by the selected cue, unless you specify a
different cue list. The selected cue is displayed just above the command line on the CIA, and at the
bottom of the live/blind screen.

The selected cue is the last cue that you affected in live. This includes a record, an update or a
playback action such as [Go], [Back] or a [Go To Cue] instruction. It is very useful to keep an eye on
the selected cue.

Using Record

[Record] will record all parameters of any channels that have non-default values to a specified cue.

To record to a new cue list press:

[Record] [2] [/] [5] [Enter] - this will create cue list 2 and will record the data to cue

5 in that cue list.

Any cues recorded after this will automatically record to cue list 2 until another cue list is specified
or the selected cue changes the cue list number.

Using Record Only

[Record Only] can be used to create a new cue list instead of [Record]. [Record Only] stores only
manual data to the specified cue.

To record to a new cue list press:

[Record Only] [2] [/] [5] - this will create cue list 2 and will record all manual data to

cue 5 in that cue list.

The cue list display will change to show only data from cue list 2. Any cues recorded after this will
automatically record to cue list 2 until another cue list is specified or the selected cue changes the
cue list.

Make Manual

This softkey can be used to convert live cue data into manual values, allowing them to be included
in the [Record Only] operation. Therefore data from other cues or lists can be selectively converted
to manual data and then stored to another cue/list using {Record Only].

For more information on {Make Manual}, see