beautypg.com

D.5.1.34 error 0082, D.5.1.35 error 0084, D.5.1.36 error 0085 – ElmoMC Multi-Axis Motion Controller-Maestro User Manual

Page 305: D.5.1.37 error 0089

background image

Action
If vnt was set to a value greater than the minimum PVT resolution supported by Elmo drives,

then vnt should be decreased. In other cases the vsp and other trajectory parameters, should be

verified.

D.5.1.34

Error 0082

Message Text
Input parameter error: Switch arc can’t be built with given switch arc radius – one of the line

segments isn’t long enough.
Explanation
To build a switch arc with given switch arc radius (input parameter svr) one the line segments

(or both) must be enlarged.
Action
Verify and fix parameters that define line segments and switch arc radius.

D.5.1.35

Error 0084

Message Text
Switch arc can't be built because the line is too close to tangent --> set zero VSC parameter

Explanation
Switch arc circle – line. Line too close to tangent so switch arc is useless and can’t be built.
Action
Set vsc = 0.

D.5.1.36

Error 0085

Message Text
Input parameter error: Switch arc radius undefined or inadequate: R_switch<1.
Explanation
The value of the input parameter switch arc radius vsr is less than 1.
Action
Set the switch arc radius to a value ≥ 1.0 (svc ≥1)

D.5.1.37

Error 0089

Message Text
Input parameter error: Vector acceleration doesn’t fit requested velocity and radius: V*V >

ACv*R
Explanation
Vector acceleration vac in a circle trajectory in fixed velocity mode. does not satisfy vsp

2

/R < vac

(where vsp is trajectory fixed velocity and R is circle radius).
Action
Verify parameters vsp, R and vac.

Maestro

Software Manual

Appendix D: Maestro System Errors

MAN-MASSW (Ver. Q)