Editing idas data channels – Teledyne 9110EH - Nitrogen Oxides Analyzer User Manual
Page 109
Model 9110EH Instruction Manual Operating Instructions
SAMPLE RANGE = 500.0 PPB NOX=X.X
< TST TST > CAL
SETUP
SETUP X.X
CONC : DATA AVAILABLE
NEXT VIEW
EXIT
SETUP X.X
ENGDAT: DATA AVAILABLE
PREV NEXT VIEW
EXIT
SETUP X.X
CALDAT: DATA AVAILABLE
PREV VIEW
EXIT
SETUP X.X
00:00:00 NXSLP1=0.000
PV10 PREV
PRM> EXIT SETUP X.X 00:00:00 NXCNC1=0.0 PPM PV10 PREV NEXT NX10 EXIT SETUP X.X 00:00:00 SMPFLW=000.0 cc / m PRM> EXIT SETUP X.X DATA ACQUISITION VIEW EDIT EXIT SETUP X.X PRIMARY SETUP MENU EXIT VIEW KEYPAD FUNCTIONS KEY FUNCTION Moves to the next Parameter PRM> Moves to the previous Parameter NX10 Moves the view forward 10 data points/channels NEXT Moves to the next data point/channel PREV Moves to the previous data point/channel PV10 Moves the view back 10 data points/channels Keys only appear as needed EXIT will return to the main SAMPLE Display. 6.10.2.3. Editing iDAS Data Channels IDAS configuration is most conveniently done through the APICOM remote control program. M9110EH Rev 0 95
CFG DAS RNGE PASS CLK MORE
The following list of key strokes shows how to edit using the front panel.
- 1220 - Multipoint flammable gas and vapor detection system (50 pages)
- 212R - Thermal conductivity analyzer (28 pages)
- 235 - Thermal conductivity analyzer (38 pages)
- 275R - Portable turbine generator purge gas analyzer (21 pages)
- 2000A-EU - General purpose thermal conductivity analyzer (86 pages)
- 2000XTC - Thermal conductivity analyzer (40 pages)
- 2010A - Split architecture thermal conductivity analyzer (110 pages)
- 2010B - Split architecture thermal conductivity analyzer (98 pages)
- 2020 - Explosion proof thermal conductivity analyzer (80 pages)
- 2120 - Trace Nitrogen in Argon Analyzer (66 pages)
- 2120XL - Trace Nitrogen Analyzer (85 pages)
- 2230R - Process Hydrogen Analyzer (26 pages)
- 2240 – Portable Handheld Hydrogen Leak Detector, 3rd generation (updated 1/31/11) (30 pages)
- 2240 - Portable Handheld Hydrogen Leak Detector, 3rd generation (revision 2/29/08) (40 pages)
- 2240 – Portable Handheld Hydrogen Leak Detector, 2nd generation (13 pages)
- 2750 - Portable turbine generator gas analzyer (40 pages)
- 300P - Percent oxygen analyzer (24 pages)
- 306WA - Analog trace oxygen analyzer (46 pages)
- 311 - Portable trace oxygen analyzer (19 pages)
- 311D - Portable trace oxygen analyzer with digital meter (18 pages)
- 311XL - Portable trace oxygen analyzer (18 pages)
- 316RA / RB / RAD / RBD - Oxygen analyzers (24 pages)
- 319R - Oxygen analyzer (23 pages)
- 320 Series - Portable oxygen detectors (24 pages)
- 326, 327 and 328 - Oxygen analyzers (45 pages)
- 329R - Oxygen analyzer (22 pages)
- 335 - Analog control room monitor for personnel safety (24 pages)
- 356WA - Analog trace oxygen analyzer (42 pages)
- 3000MA - Paramagnetic oxygen analyzer (63 pages)
- 3000MA - Paramagnetic oxygen analyzer Addendum (2 pages)
- 3000MB - Paramagnetic oxygen analyzer (59 pages)
- 3000PA - General purpose percent oxygen analyzer (69 pages)
- 3000PAEU - General purpose percent oxygen analyzer (78 pages)
- 3000PB - Bulkhead mount percent oxygen analyzer (82 pages)
- 3000TA - General purpose trace oxygen analyzer (75 pages)
- 3000TA-EU - General purpose trace oxygen analyzer (89 pages)
- 3000TA-XLEU - Trace oxygen analyzer (108 pages)
- 3000TB - Bulkhead mount trace oxygen analyzer (78 pages)
- 3000TB-XL - Trace oxygen analyzer (78 pages)
- 3000ZA - Trace oxygen analyzer (81 pages)
- 3000ZA-3X - Trace oxygen analyzer (72 pages)
- 3000ZA2G - Zirconium oxide analyzer (72 pages)
- 3000 Ultra Trace - PPB oxygen analyzer (72 pages)
- 3010MA - Paramagnetic oxygen analyzer, includes 0-100% range (88 pages)
- 3010MA – Paramagnetic oxygen analyzer, no 0-100% range – (superceded) (88 pages)