beautypg.com

Nt8d17 conference/tds card, Nt8d21 ringing generator ac – Nortel Networks Circuit Card 311 User Manual

Page 96

background image

96

Option settings

NT8D17 Conference/TDS card

Switch and jumper settings are used to select the companding law and to
change the conference attenuation PAD levels. These PAD levels are used
if prompt CPAD = 1 in LD97. The J1 connector on the faceplate is reserved
for future use.

You can enable or disable a warning tone for conference calls. When the
option is enabled, the tone lets callers know they are entering a conference
call. The switch for this option is preset to disable the warning tone.

Companding law

Jumper at J3

µ

-law (North America), A-law

connect pins 2 and 3

Special cases

connect pins 1 and 2

SW2 (see Note)

Attenuation levels

1

2

3

10.2 db

on

on

on

8.5 db

on

off

on

6 db

off

on

on

6 db

off

off

on

4.5 db

on

on

off

3 db

on

off

off

0 db

off

on

off

0 db

off

off

off

Note: Set position 4 to ON to disable the warning tone option. When the warning tone is enabled,
select the warning tone level as shown below.

Level

Jumper at J2

24 db

connect pins 1 and 2

30 db

connect pins 2 and 3

NT8D21 Ringing Generator AC

Settings

Frequency

Amplitude

P1

P2

P3

20 Hz

86 V ac

open

open

2–5

8–11

25 Hz

70 V ac

open

1–4

7–10

open

25 Hz

80 V ac

open

3–6

9–12

open

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.