NT5D11 and NT5D14 Lineside T1 Interface cards

Unavailable seconds – unavailable state starts with 10 consecutive
severely errored seconds and ends with 10 consecutive severely errored
seconds (excluding the final 10 non-severely errored seconds). Severely
errored seconds are defined as more than 320 CRC-6 errors, or one or
more out of frames in a second.

Loss of frame seconds – loss of frame or loss of signal for three
consecutive seconds

Framer slip seconds – one ore more frame slips in a second

The MMI also maintains an overall error counter that is a sum of all the
errors counted for the five performance criteria listed above. The error
counter can only be cleared by entering the "Clear Error" command. It
stops counting at 65,000. The error counter provides an easy method to
determine if an alarm condition has been corrected. Simply clear the error
counter, wait a few minutes, and display performance to see if any errors
occurred since the counter was cleared.

Display the reports on these performance counters by entering the Display
Performance (D P) or the Display History (D H) command sets into the MMI.

Display Performance

Enter the Display Performance (D P) command set to display performance
counters for the past hour. A screen similar to the following appears:

LTI T1 Interface Performance Log

3/03/95 1:37

Data for the past 37 Minutes

Errored

Bursty

Unavailable

Loss Frame

Frame Slip

Error

Seconds

Seconds

Seconds

Seconds

Seconds

Counter

2263

0

2263

2263

352

321

Each column, except the error counter, indicates the number of errors in
the current hour and is reset to zero every hour on the hour. When these
counters are reset to zero, the performance counter values are put into the
history log. The error counter indicates the number of errors that occurred
since the error counter was cleared.

Display History

Enter the Display History (D H) command set to display performance
counters for each hour for the past 24 hours. A screen similar to the
following appears:

LTI T1 Interface History Performance Log

3/03/95 1:35

Hour

Errored

Bursty

Unavailable

Loss Frame

Frame Slip

Error