Nortel Networks Circuit Card 311 User Manual
Page 1100

1100
QPC513 Enhanced Serial Data Interface card
Mode
Port
Jumper socket
designations
Data communication equipment (DTE)
2
UA17
UA19
Data terminal equipment (DCE)
2
UA16
UA18
Table 449
ESDI card RS-232-C/high-speed interface jumper settings
Mode
Port
Jumper socket
designations
RS-232-C interface
1
UB9
UB11
High-speed interface
1
UB10
UB12
RS-232-C interface
2
UB16
UB18
High-speed interface
2
UB17
UB19
Software service changes
All of the other ESDI port operating parameters are defined in software and
downloaded to the assigned ESDI port. See
of synchronous ports" (page 1093)
. These changes are made using the
Configuration Record program (LD 17). Instructions for the Configuration
Record program are found in the Software Input/Output Reference —
Administration (NN43001-611).
Some of the prompts that are commonly used when running the
Configuration Record program (LD 17) are shown in
Serial port configuration parameters." (page 1100)
These parameters must
be set for each ports if both ports are being used.
Table 450
LD 17 - Serial port configuration parameters.
Prompt
Response
Description
REQ:
CHG
Change configuration.
TYPE:
CFN
Configuration type.
IOTB
YES
Change input/output devices.
ADAN
NEW TTY x
NEW PRT x
Define a new system terminal (printer) port as device x, where x
= 0 to 15.
CDNO
1-16
Use the ESDI card number to keep track of all ports.
DENS
DDEN
Double density SDI paddle board.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.