QPC513 Enhanced Serial Data Interface card

Mode

Port

Jumper socket

designations

Data communication equipment (DTE)

2

UA17

UA19

Data terminal equipment (DCE)

2

UA16

UA18

Table 449
ESDI card RS-232-C/high-speed interface jumper settings

Mode

Port

Jumper socket

designations

RS-232-C interface

1

UB9

UB11

High-speed interface

1

UB10

UB12

RS-232-C interface

2

UB16

UB18

High-speed interface

2

UB17

UB19

Software service changes

All of the other ESDI port operating parameters are defined in software and
downloaded to the assigned ESDI port. See

Table 443 "Characteristics

of synchronous ports" (page 1093)

. These changes are made using the

Configuration Record program (LD 17). Instructions for the Configuration
Record program are found in the Software Input/Output Reference —
Administration
(NN43001-611).

Some of the prompts that are commonly used when running the
Configuration Record program (LD 17) are shown in

Table 450 "LD 17 -

Serial port configuration parameters." (page 1100)

These parameters must

be set for each ports if both ports are being used.

Table 450
LD 17 - Serial port configuration parameters.

Prompt

Response

Description

REQ:

CHG

Change configuration.

TYPE:

CFN

Configuration type.

IOTB

YES

Change input/output devices.

ADAN

NEW TTY x

NEW PRT x

Define a new system terminal (printer) port as device x, where x
= 0 to 15.

CDNO

1-16

Use the ESDI card number to keep track of all ports.

DENS

DDEN

Double density SDI paddle board.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008