Connector pin assignments, Configuration, Table 423 ntck16 pad switching – Nortel Networks Circuit Card 311 User Manual
Page 1006

1006
NTCK16 Generic Central Office Trunk cards
Table 423
NTCK16 pad switching
Loss
Analog-to-Digital
Digital-to-Analog
PAD out
0 dB
–3 dB
PAD in
+4 dB
+1 dB
Note: The tolerance for the above nominal values is +0.3 dB, -0.7 dB.
Connector pin assignments
Cross connections
,
Figure 283 "NTCK16 Central Office
trunk connections for NT8D37 I/O panel connectors B, F, L, S" (page 1008)
,
and
Figure 284 "NTCK16 Central Office trunk connections for NT8D37 I/O
panel connectors C, G, M, T" (page 1009)
provide cross connect information
for the NTCK16AX and NTCK16BX generic Central Office trunk cards.
Configuration
The trunk type for each unit on the card is selected by software service
change entries at the system terminal.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.