Nortel Networks Circuit Card 311 User Manual
Page 94

94
Option settings
Table 32
NT8D14 vintages BA/BB jumper strap settings-extended range
Jumper strap settings
Trunk types
Loop length
J1.X
J2.X
J3.X
J4.X
CO/FX/WATS
2-way tie (LDR)
2-way tie (OAID)
> 1524 m (5000 ft)
Off
Off
1–2
2–3
DID
> 600 ohms
On
On
1–2
2–3
RAN: pulse start or level
start modes
Not applicable: RAN
trunks should not leave the
building.
Off
Off
2–3
1–2
Note: Jumper strap settings J1.X, J2.X, J3.X, and J4.X apply to all eight units; "X" indicates the unit
number, 0–7. "Off" indicates that no jumper strap is installed on a jumper block.
Table 33
NT8D14 vintages BA/BB trunk types-termination impedance and balance network
Balance network for loop lengths (Note 2)
Trunk types
Terminating
impedance
(Note 1)
Zero–915 m
(zero–3000 ft)
915–1524 m
(3000–5000 ft)
> 1524 m
(> 5000 ft)
CO/FX/WATS
600 or 900 ohms
600 ohms
3COM1
3COM2
2-way tie (LDR)
600 or 900 ohms
600 ohms
3COM1
3COM2
2-way tie (OAID)
600 or 900 ohms
600 ohms
3COM1
3COM2
DID (loop < 600
ohms)
600 or 900 ohms
600 ohms
3COM1
3COM2
DID (loop ˇ
S 600
ohms)
600 or 900 ohms
600 ohms
N/A
3COM2
RAN: continuous
operation mode
600 or 900 ohms
600 or 900 ohms
N/A
N/A
Paging
600 ohms
600 ohms
N/A
N/A
Note 1: The terminating impedance of each trunk unit is software selectable in LD 14 and should
match the nominal impedance of the connecting equipment.
Note 2: The balance network of each trunk unit is software selectable between resistive 600 or 900
ohms or 3COM and is jumper selectable between 3COM1 and 3COM2.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.