Figure 166 "ground start call connection – Nortel Networks Circuit Card 311 User Manual

Page 611

background image

Operation

611

Figure 166
Ground start call connection sequence - outgoing call to CO/FX/WATS

For outgoing calls, the trunk provides a ground to the ring lead. The CO
responds by grounding the tip and returning dial tone. After the tip ground is
detected by the card, a low-resistance path is placed between the tip and
ring leads and the ground is removed from the ring. Addressing is then
applied from the CS 1000 in the form of loop (interrupting) dial pulses or

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008