NT7D16 Data Access card
— Disabled—On with DTR (normal)
— Enabled—Off with DTR (modes 8 or 12, and no DTR for 5 seconds)
•
Auto Baud
— Variable (use auto baud rate)
— Fixed (use baud rate selection only)
•
Baud rate
— 110
— 150
— 300
— 600
— 1200
— 2400
— 4800
— 9600
— 19200
•
Operating mode
— DCE
— DTE
•
Equipment type
— Terminal (send prompts/replies)
— Host (suppress prompts/replies)
•
Long Break Detect
In
Table 161 "Clock Controller options - summary" (page 353)
and
104 "MSDL switch setting example" (page 402)
, the rectangles represent
the settings of service change parameters in LD11 that affect the desired
function. The diamonds represent the logical DAC operating mode
decisions.
Upload parameters
The system can, at any time, request information from a DAC port. The
uploaded parameters contain information about the individual card (card
type, order code, release information), as well as the status of the configured
operating parameters. Because the dialogue operations of data calls can