NT5D11 and NT5D14 Lineside T1 Interface cards

Command

Description

A E

Alarm Enable
Enables all alarms.

C A

Clear Alarm
Clears all alarms, terminates line processing, and resets the T1 bit error rate
and frame slip counters.

C A L

Clear Alarm Log
Clears the alarm log.

C E

Clear Error
Clears the error counter for the T1.

D A [P]

Display Alarms [Pause]
Displays the alarm log – a list of the most recent 100 alarms along with time
and date stamps.

D C

Display Configuration
Displays the configuration settings for the cards including:

the serial number of the card

MMI firmware version

date and time

alarm enable/disable setting

self-clearing enable/disable setting

settings entered in Set Configuration

dip switch settings

D H [P]

Display History [Pause]
Displays performance counters for the past 24 hours.

D P

Display Performance
Displays performance counters for the current hour.

D S [P]

Display Status [Pause]
Displays carrier status, including whether the card is in the alarm state, and
what alarm level is currently active.

H or ?

Help
Displays the help screen.

L

Login
Logs into the MMI terminal when the system has one Lineside T1 card.

Q

Quit
Logs the terminal user out. If multiple Lineside T1 cards share a single terminal,
logout after using the MMI. Because of the shared daisy-chained link, if a
Lineside T1 card is logged in, it occupies the bus and no other Lineside T1
cards are able to notify the MMI of alarms.