Nortel Networks Circuit Card 311 User Manual
Page 232

232
NT5D11 and NT5D14 Lineside T1 Interface cards
Command
Description
A E
Alarm Enable
Enables all alarms.
C A
Clear Alarm
Clears all alarms, terminates line processing, and resets the T1 bit error rate
and frame slip counters.
C A L
Clear Alarm Log
Clears the alarm log.
C E
Clear Error
Clears the error counter for the T1.
D A [P]
Display Alarms [Pause]
Displays the alarm log – a list of the most recent 100 alarms along with time
and date stamps.
D C
Display Configuration
Displays the configuration settings for the cards including:
•
the serial number of the card
•
MMI firmware version
•
date and time
•
alarm enable/disable setting
•
self-clearing enable/disable setting
•
settings entered in Set Configuration
•
dip switch settings
D H [P]
Display History [Pause]
Displays performance counters for the past 24 hours.
D P
Display Performance
Displays performance counters for the current hour.
D S [P]
Display Status [Pause]
Displays carrier status, including whether the card is in the alarm state, and
what alarm level is currently active.
H or ?
Help
Displays the help screen.
L
Login
Logs into the MMI terminal when the system has one Lineside T1 card.
Q
Quit
Logs the terminal user out. If multiple Lineside T1 cards share a single terminal,
logout after using the MMI. Because of the shared daisy-chained link, if a
Lineside T1 card is logged in, it occupies the bus and no other Lineside T1
cards are able to notify the MMI of alarms.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.