NT8D14 Universal Trunk card

Figure 142
Universal trunk card - faceplate

The faceplate of the card is equipped with a red Light Emitting Diode
(LED). See

Figure 142 "Universal trunk card - faceplate" (page 574)

. When

an NT8D14 Universal Trunk Card is installed, the LED remains lit for two
to five seconds while the self-test runs. If the self-test is successful, the
LED flashes three times and remains lit. When the card is configured and
enabled in software, then the LED goes out. If the LED flashes continuously
or remains weakly lit, replace the card.