beautypg.com

Nortel Networks Circuit Card 311 User Manual

Page 1015

background image

Applications

1015

LD 97 - Defining Loss Switching mode.

Prompt

Response

Description

REQ:

CHG

TYPE:

SYSP

IPE system parameters configuration

...

NATP

YES

Select North American transmission plan.

Note: The default to the NATP prompt is NO, and therefore this
prompt must always be checked during installation.

2. Define Loss Switching Class Of Service. Respond to the prompts in

LD 14 as shown.

LD 14 - Defining Loss Switching Class Of Service.

Prompt

Response

Description

REQ:

CHG

TYPE:

COT

XTRK

XCOT

SIGL

LOP

...

CLS

LOL

LOL= Long Line

Note: The XFCOT uses the CLS Long Line (LOL) and Short
Line (SHL) for Loss Switching purposes and that the card and
trunk type is different from the XUT.

Equivalencies

The following equivalencies do apply:

XFCOT COT SHL is equivalent with XUT COT TRC

XFCOT COT LOL is equivalent with XUT COT NTC.

The entries TRC and NTC are no longer allowed for the Generic XFCOT.

Trunk to Trunk connection

When any disconnect supervision is configured (CLS = BAT, BTS), the
Loop Start Trunk of the Generic XFCOT is marked as having disconnect
supervision and therefore follows the same rules as a Ground Start Trunk.

There is no configuration involved for this operation.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008