LD 97 - Defining Loss Switching mode.
Prompt
Response
Description
REQ:
CHG
TYPE:
SYSP
IPE system parameters configuration
...
NATP
YES
Select North American transmission plan.
Note: The default to the NATP prompt is NO, and therefore this
prompt must always be checked during installation.
2. Define Loss Switching Class Of Service. Respond to the prompts in
LD 14 as shown.
LD 14 - Defining Loss Switching Class Of Service.
Prompt
Response
Description
REQ:
CHG
TYPE:
COT
XTRK
XCOT
SIGL
LOP
...
CLS
LOL
LOL= Long Line
Note: The XFCOT uses the CLS Long Line (LOL) and Short
Line (SHL) for Loss Switching purposes and that the card and
trunk type is different from the XUT.
Equivalencies
The following equivalencies do apply:
•
XFCOT COT SHL is equivalent with XUT COT TRC
•
XFCOT COT LOL is equivalent with XUT COT NTC.
The entries TRC and NTC are no longer allowed for the Generic XFCOT.
Trunk to Trunk connection
When any disconnect supervision is configured (CLS = BAT, BTS), the
Loop Start Trunk of the Generic XFCOT is marked as having disconnect
supervision and therefore follows the same rules as a Ground Start Trunk.
There is no configuration involved for this operation.