Nortel Networks Circuit Card 311 User Manual
Page 1010

1010
NTCK16 Generic Central Office Trunk cards
LD 16 - Route Data Block for NTCK16AX.
Prompt
Response
Description
REQ:
NEW
Define a new unit
TYPE:
COT
Define a new Route Data Block
CUST
xx
Customer number as defined in LD 15.
ROUT
Route number
0-511
Range for Large System, Call Server 1000E, and
Media Gateway 1000E
0-127
Range for Small System, CS 1000E system,
Media Gateway 1000B, and
Media Gateway 1000T
TKTP
COT
Define trunk type as Central Office
ICOG
IAO
Incoming and Outgoing trunk
CNTL
YES
Change a trunk timer
TIMER
RGV 256
Set Ring Validation Timer to 128 ms.
MR
(NO) PPM XLD
PPM is off, buffered, or unbuffered on this route.
Trunk Data Block
Respond to the prompts in LD 14 as shown:
LD 14 - Trunk Data Block for NTCK16AX.
Prompt
Response
Description
REQ:
NEW
Define a new trunk unit
TYPE:
COT
Central Office Trunk
TN
Terminal Number
l s c u
Format for Large System, Call Server
1000E, and Media Gateway 1000E,
where l = loop, s = shelf, c = card, u
= unit
XTRK
(See note on
.)
XCOT
Type is IPE COT
CDEN
(8D)
Card density is 8D (default)
SIGL
LOP
Loop start signaling
PPID
(See
.)
Xx
04 Ireland/Turkey 12 KHz
03 Turkey 16 KHz
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.