Installation and configuration

197

MMI Master or Slave

This setting is used only if daisy-chaining the cards to the MMI terminal or
modem. This setting determines whether this card is a master or a slave in
the MMI daisy-chain. Select the master setting if this card is the card that is
cabled directly into the MMI terminal or modem; select the slave setting if
this card is cabled to another Lineside T1 card in a daisy chain.

Table 91 "Lineside T1 card-T1 Switch 1 (S1) dip switch settings" (page
197)

through

Table 94 "Lineside T1 card - CPE or CSU distance dip switch

settings (Switch S2, positions 3 - 5)" (page 198)

describe the proper dip

switch settings for each type of T1 link. After the card has been installed, the
MMI displays the DIP switch settings the command Display Configuration
is used. See

"Functional description" (page 391)

for details on how to

invoke this command.

Table 91
Lineside T1 card-T1 Switch 1 (S1) dip switch settings

Dip Switch

Number

Characteristic

Selection

1

MMI port speed selection

On = 1200 baud
Off = 2400 baud

2

T1 signaling

On = Ground start
Off = Loop start

3–6

XPEC Address for the Lineside T1 card

See

Table 92 "Lineside

T1 card - XPEC address
dip switch settings (Switch
S1, positions 3 - 6)" (page
197)

.

7

Not Used

Leave Off

8

Reserved for SL-100 use

Leave Off

Table 92
Lineside T1 card - XPEC address dip switch settings (Switch S1, positions 3 - 6)

XPEC

Address

S1 Switch
Position 3

S1 Switch
Position 4

S1 Switch
Position 5

S1 Switch
Position 6

00

Off

Off

Off

Off

01

Off

Off

Off

On

02

Off

Off

On

Off

03

Off

Off

On

On

04

Off

On

Off

Off

05

Off

On

Off

On

06

Off

On

On

Off

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008