Table 222 power requirements – Nortel Networks Circuit Card 311 User Manual
Page 555

Electrical specifications
555
Table 222
Power requirements
Voltage
(+/-)
Tolerance
Idle
current
Active
current
Max
+ 12.0 V dc
0.36 V dc
48 mA
0 mA
48 mA
+ 8.0 V dc
0.40 V dc
150 mA
8 mA
280 mA
–48.0 V dc
2.00 V dc
48 mA
40 mA
688 mA
–48.0 V dc
5.00 V dc
0 mA
10 mA
(Note 1)
320 mA
86.0 V ac
5.00 V ac
0 mA
10 m
(Note 2)
160 mA
–150.0 V dc
3.00 V dc
0 mA
2 mA
32 mA
Note 1: Each active ringing relay requires 10 mA of battery voltage.
Note 2: Reflects the current for ringing a single station set. There may be as
many as five ringers on each line.
Foreign and surge voltage protections
In-circuit protection against power line crosses or lightning is not provided
on the NT8D09 Analog Message Waiting line card.
In-circuit protection against power line crosses or lightning is not provided
on the analog message waiting line card. When the card is used to service
off-premise telephones, primary and secondary MDF protection must be
installed. Details on installing protection devices are given in
. Off-premise telephones served by cable pairs
routed through the central office, or crossing a public right-of-way, can be
subject to a requirement for on-card protection, and MDF protectors may
not be acceptable. Check local regulations before providing such service.
In-circuit protection against power line crosses or lightning is not provided on
the Analog Message Waiting line card. When the Analog line card is used to
service off-premise telephones, the NTAK92 Off-premise protection module
must be used. Check local regulations before providing such service.
In-circuit protection against power line crosses or lightning is not provided
on the NT8D09 Analog Message Waiting Line Card. When the analog line
card is used to service off-premise telephones, the NTAK92 Off-Premise
protection module must be used. Check local regulations before providing
such service.
Overload level
Signal levels exceeding +7 dBm applied to the tip and ring cause distortion
in speech transmission.