beautypg.com

Table 238 power requirements – Nortel Networks Circuit Card 311 User Manual

Page 681

background image

Electrical specifications

681

Characteristic

DID trunk

CO trunk

Signaling type

Loop start

Ground or loop start

Far end battery

- 42 to - 52.5 V

- 42 to - 52.5 V

Near end battery

N/A

- 42.75 to - 52.5 V

Minimum loop current

N/A

20 mA

Ground potential difference

+ 3 V

+ 3 V

Low DC loop resistance
during outpulsing

N/A

< 300 ohms

High DC loop resistance

N/A

Ground start equal to or greater
than 30 kohms; loop start equal
to or greater than 5 Mohms

Line leakage

Equal to or greater than 30 kohms
(tip to ring, tip to ground, ring to
ground)

Equal to or greater than 30 kohms
(tip to ring, tip to ground, ring to
ground)

Effective loss

See

"PAD switching" (page 684)

See

"PAD switching" (page 684)

Power requirements

Power to the NT8D14 Universal Trunk card is provided by the module power
supply (ac or dc).

Table 237
Power requirements for universal trunk card

Voltage

Tolerance

Current (max.)

+15.0 V dc

±5%

306 mA

–15.0 V dc

±5%

306 mA

+5.0 V dc

±5%

750 mA

+8.5 V dc

±2%

450 mA

–48.0 V dc

±5%

415 mA

Power to the universal trunk card is provided by the module power supply
(ac or dc).

Table 238 "Power requirements" (page 681)

lists the power

requirements for the universal trunk card.

Table 238
Power requirements

Voltage

Tolerance

Current (max.)

+15.0 V dc

±5%

306 mA

–15.0 V dc

±5%

306 mA

+5.0 V dc

±5%

750 mA

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.