The TRC and NTC COS options determine the operation of the switchable
pads contained in the trunk circuits. They are assigned as follows:

TRC for a two-wire non-VNL trunk facility with a loss of greater than 2
dB or for which impedance compensation is provided, or for a four-wire
non-VNL facility.

NTC for a two-wire non-VNL trunk facility with a loss of less than 2 dB or
when impedance compensation is not provided.

In Option 11C systems,

Table 310 "Insertion Loss from IPE Ports to IPE

Ports (measured in dB)" (page 797)

shows the insertion loss from IPE port

to IPE port.

Table 310
Insertion Loss from IPE Ports to IPE Ports (measured in dB)

Paging trunk operation

When used in the paging mode, a trunk is connected to a customer-provided
paging amplifier system (not zone selectable). When the trunk is accessed
by dial-up or attendant-key operation, it provides a loop closure across