Functional description
731
•
Four-wire E and M signaling type I and II, two-way dial repeating (ESN
and Non-ESN)
— echo suppression for type I
— Switchable seven dB and 16 dB for carrier interface for ESN
applications
— Transmit and receive of voice through two separate paths
•
Type I signaling through E and M leads
— Type II signaling
–
Near-end seizure with MA/MB leads
–
Far-end detection with EA/EB leads
•
Paging trunk loop OAID operation
— Support access by low resistance path at the PA/PB lead.
— All call zone paging is not supported.
•
Two to four-wire conversion of the transmission path
Trunk unit functions
The functions provided by each unit on the E and M Trunk card include
2-wire signaling, 4-wire signaling, and paging operation as follows:
•
2-wire, E and M Type I signaling (see
) with:
— near-end seizure and outpulsing with M lead
— ground detection with E lead
— voice transmission through tip and ring for transmit and receive
•
4-wire, E and M Type I and II signaling (see
), 2-way dial repeating with:
— echo suppression for Type I signaling
— switchable 7 dB and 16 dB pads for carrier interface
— voice transmission and reception through two separate paths
— Type I signaling through E and M leads
— Type II signaling with near-end seizure by SB/M leads and far-end
detection by E/SG lead
•
4-wire, DX signaling (see
Figure 230 "4-wire DX signaling" (page 734)
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.