beautypg.com

Nortel Networks Circuit Card 311 User Manual

Page 233

background image

Man-Machine T1 maintenance interface software

233

Command

Description

S A

Set Alarm parameters
Alarm parameters include the allowable bit errors per second threshold and
alarm duration.

S C

Set Clearing
Sets the alarm self-clearing function to either enable or disable.

S D

Set Date
Sets date or verifies current date.

S T

Set time
Sets time or verifies current time.

T x

Test
Initiates the T1 carrier test function. To terminate a test in process, enter the
STOP TEST (S) command at any time.

MMI commands can now be executed. There are seven basic commands
that can be combined together to form a total of 19 command sets. They are:

Alarm

Clear

Display

Set

Test

Help

Quit

If

?

is typed, the MMI lists the above commands along with an

explanation of their usage. A screen similar to the following appears. The
help screen also appears by typing

H

, or

HELP

.

ALARM

USAGE: Alarm [Enable | Disable]

CLEAR

USAGE: Clear [Alarm] | [Error counter] [Log]

DISPLA
Y

USAGE: Display [Alarm | Status | Perform | History] [Pause]

HELP

USAGE: Help | ?

SET

USAGE: Set [Time | Date | Alarm | Clearing | Name | Memory]

TEST

USAGE: Test [Carrier All]

QUIT

USAGE: Quit

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.