Nortel Networks Circuit Card 311 User Manual
Page 233

Man-Machine T1 maintenance interface software
233
Command
Description
S A
Set Alarm parameters
Alarm parameters include the allowable bit errors per second threshold and
alarm duration.
S C
Set Clearing
Sets the alarm self-clearing function to either enable or disable.
S D
Set Date
Sets date or verifies current date.
S T
Set time
Sets time or verifies current time.
T x
Test
Initiates the T1 carrier test function. To terminate a test in process, enter the
STOP TEST (S) command at any time.
MMI commands can now be executed. There are seven basic commands
that can be combined together to form a total of 19 command sets. They are:
•
Alarm
•
Clear
•
Display
•
Set
•
Test
•
Help
•
Quit
If
?
is typed, the MMI lists the above commands along with an
explanation of their usage. A screen similar to the following appears. The
help screen also appears by typing
H
, or
HELP
.
ALARM
USAGE: Alarm [Enable | Disable]
CLEAR
USAGE: Clear [Alarm] | [Error counter] [Log]
DISPLA
Y
USAGE: Display [Alarm | Status | Perform | History] [Pause]
HELP
USAGE: Help | ?
SET
USAGE: Set [Time | Date | Alarm | Clearing | Name | Memory]
TEST
USAGE: Test [Carrier All]
QUIT
USAGE: Quit
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008
Copyright © 2003-2008, Nortel Networks
.