NT5D97 Dual-port DTI2 PRI2 card
Table 147
Trunk interface impedance switch settings
Description
S8/S14 switch setting
75 ohm
OFF
OFF
ON
OFF
120 ohm
OFF
OFF
OFF
ON
Ring ground switches for NT5D97AA/AB
A set of four Dip switches (S2) selects which Ring lines are connected to
ground. Refer to
Table 148 "Ring ground switch settings" (page 344)
.
Table 148
Ring ground switch settings
Switch
Description
S2 switch settingS
1
Trunk 0 Transit
OFF-Ring line is not grounded
ON- Ring line is grounded
2
Trunk 0 Receive
OFF-Ring line is not grounded
ON- Ring line is grounded
3
Trunk 1 Transmit
OFF-Ring line is not grounded
ON- Ring line is grounded
4
Trunk 1 Receive
OFF-Ring line is not grounded
ON- Ring line is grounded
DCH Address select switch for NTBK51AA daughterboard for
NT5D97AA/AB
In case of an on-board NTBK51AA D-channel daughterboard, set of four
switches (S3) provide the daughterboard address. Refer to
Note: Switch 8 of S3 (S3-8) does not require a switch setting to select
between the on-board NTBK51AA D-channel daughterboard and
an external DCHI/MSDL. The NT5D97 detects when the on-board
NTBK51AA D-channel daughterboard is used.
Table 149
DCH mode and address switch settings
Swit
ch
Description
S3 switch setting
1-4
D-channel daughterboard address
See
"NTBK51AA
daughterboard
address select switch
settings" (page 345)
5-8
For future use
OFF