Functional description

545

20-Hz ringing signal connection and automatic disconnection when the
station goes off-hook

synchronization for connecting and disconnecting the ringing signal
to zero crossing of ringing voltage

loopback of SSD messages and pulse code modulation (PCM) signals
for diagnostic purposes

correct initialization of all features at power-up

direct reporting of digit dialed (500-type telephones) by collecting dial
pulses

connection of -150 V DC at 1 Hz to activate message waiting lamps

lamp status detection

disabling and enabling of selected units for maintenance

The NT8D09 Analog Message Waiting Line Card contains a microprocessor
that provides the following functions:

self-identification

self-test

control of card operation

status report to the controller

maintenance diagnostics

The NT8D09 Analog Message Waiting Line Card also provides the following:

600 ohms balanced terminating impedance

analog-to-digital and digital-to-analog conversion of transmission and
reception signals for 16 audio phone lines

transmission and reception of Scan and Signaling Device (SSD)
signaling messages over a DS-30X signaling channel in A10 format

on-hook/off-hook status and switchhook flash detection

20 Hz ringing signal connection and automatic disconnection when the
station goes off-hook

synchronization for connecting and disconnecting the ringing signal
to zero crossing of ringing voltage

loopback of SSD messages and Pulse Code Modulation (PCM) signals
for diagnostic purposes

correct initialization of all features at power-up

direct reporting of digit dialed (500-type telephones) by collecting dial
pulses

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311