NT1R20 Off-Premise Station Analog Line card

The OPS analog line card uses only eight of the 30 available timeslots for
its eight line interfaces. The OPS analog line card can be configured in
software to format PCM data in the µ-law or A-law conventions.

Maintenance communication

Maintenance communication is the exchange of control and status data
between line or trunk cards and the CPU. Maintenance data is transported
through the card LAN link.

The card LAN link supports the following functions on the NT1R20 OPS
analog line card:

polling

reporting of self-test status

CPU initiated card reset

reporting of card ID (card type and hardware vintage)

reporting of firmware version

reporting of line interface unit configuration

enabling/disabling of the DS-30X network loop busy

reporting of card status

Maintenance communications

Maintenance communications is the exchange of control and status data
between line or trunk cards and the CPU. Maintenance data is transported
via the card LAN link.

The card LAN link supports the following functions on the OPS analog line
card:

polling

reporting of self-test status

CPU initiated card reset

reporting of card ID (card type and hardware vintage)

reporting of firmware version

reporting of line interface unit configuration

enabling/disabling of the DS-30X network loop busy

reporting of card status

Maintenance communication

Maintenance communication is the exchange of control and status data
between line or trunk cards and the CS 1000 CPU. Maintenance data is
transported through the card LAN link.