Nortel Networks Circuit Card 311 User Manual

Page 625

background image

Operation

625

Figure 178
Two-way, loop DR, TIE trunk call connection sequence - incoming call from far-end PBX

In an incoming call configuration, the far-end initiates a call by placing a
low-resistance loop across the tip and ring leads. See

Figure 187 "Two-way,

loop DR, tie trunk call states - incoming call from far-end PBX" (page
635)

and

Figure 188 "Two-way, loop DR, tie trunk call connection sequence

- incoming call from far-end PBX" (page 636)

on. This causes a current to

flow through the battery feed resistors in the trunk circuit. Address signaling
is then applied by the far-end in the form of DTMF tones or dial pulses.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008