beautypg.com

Figure 77 test parameters screen, Table 127 mmi tests – Nortel Networks Circuit Card 311 User Manual

Page 312

background image

312

NT5D33 and NT5D34 Lineside E1 Interface cards

terminate at the end of the time period or when a

Stop Test

command

is issued. Only

Stop Test

stops a test with a duration selection of 99;

however, the

STOP

command terminates a test set to any duration from one

to 99. After entering the test number, a prompt similar to

Figure 77 "Test

parameters screen" (page 312)

appears.

Figure 77
Test parameters screen

Before a test is run, be sure to verify that the card is disabled, as the tests
interfere with calls currently in process.

During a test, if an invalid word is received, this is recorded by a failure
peg counter. The peg counter has a limit of 65,000. At the end of the test,
the Test Results message indicates how many failures, if any, occurred
during the test.

Table 127 "MMI Tests" (page 312)

shows which test to run for the associated

equipment.

Table 127
MMI Tests

Test number

Equipment Tested

Test Description

1

LEI

Local loopback

2

E1 link, LEI, and E1
network

External loopback

3

CPE device and E1
network

Network loopback

Test 1, local loopback, loops the E1 link signaling toward itself at the
backplane connector. Test data is generated and received on all timeslots.
If this test fails, it indicates that the LEI is defective.

Figure 78 "MMI Local

loopback test" (page 313)

illustrates how the signaling is looped back

toward itself.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.