beautypg.com

Figure 72 display alarm (d a) screen, Displa – Nortel Networks Circuit Card 311 User Manual

Page 308

background image

308

NT5D33 and NT5D34 Lineside E1 Interface cards

Clear Alarm

The

Clear Alarm (C A)

command clears all activity initiated by an

alarm: the external alarm hardware is deactivated (the contact normally
open is reopened), the LED goes out, an entry is made in the alarm log
of the date and time the alarm was cleared, and line processing ceases
(for alarm level 2 only). When this command is typed, MMI displays the
message Alarm acknowledged. If the alarm condition still exists, an alarm
is declared again.

Display Alarms

A detailed report of the most recent 100 alarms with time and date stamps
can be displayed by entering the

Display Alarms (D A)

command into

the MMI, which causes a screen similar to

Figure 72 "Display Alarm (D A)

screen" (page 308)

to appear.

Figure 72
Display Alarm (D A) screen

The Pause command can be used to display a full screen at a time, by
entering

D A P

. If there is more than one screen in the log, the MMI scrolls

the log until the screen is full, then stops. When ready to see the next
screen, press any key. The display shows another screen and stops again.
This continues until the entire log has been displayed.

Clear Alarm Log

Clear all entries in the alarm log by typing the

Clear Alarm Log (C

A L)

command.

Display Status

The

Display Status (D S)

command displays the current alarm

condition of the E1 link as well as the on-hook or off-hook status of each of
the 30 ports of the LEI. Entering this command causes a screen similar to

Figure 73 "Display Status (D S) screen" (page 309)

to appear.

The Pause command can be used to display a full screen at a time, by
entering

D S P

. If there is more than one screen, the MMI scrolls until the

screen is full, then stops. When ready to see the next screen, press any
key. The display shows one more screen, and stops again. This continues
until the entire E1 link has been reported on.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.