No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

T2-14

(0737)

PM Motor Induced

Voltage Constant

Induct Volt Coef

OLV/PM

OLV/PM

Enter the induced voltage coefficient for the PM motor as

indicated on the motor nameplate. Setting units are determined

by parameter T2-13, Induced Voltage Constant Unit Selection.

Default:

<3>

Min.: 0.1

Max.: 2000.0

T2-15

(0756)

Pull-In Current Level for

PM Motor Tuning

Pull-In I Lvl

OLV/PM

OLV/PM

Sets the amount of pull-in current to use for Auto-Tuning as a

percentage of the motor rated current. Increase this setting for

high inertia loads.

Default: 30%

Min.: 0

Max.: 120

<1> Default setting is determined by parameters A1-02, Control Method Selection, and o2-04, Drive Model Selection.
<3> Default setting is dependent on parameter T2-02, PM Motor Code Selection, and the drive capacity.
<4> Default setting is determined by parameter o2-04, Drive Model Selection.
<5> Values shown are specific to 200 V class drives. Double the value for 400 V class drives.