No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

E5-03

(032B)

<1>

Motor Rated Current

(for PM Motors)

PM Mtr Rated FLA

OLV/PM

OLV/PM

Sets the motor rated current.

Default:

<3>

Min: 10% of

drive rated

current

Max: 150% of

drive rated
current

<5>

123

E5-04

(032C)

<1>

Number of Motor Poles

(for PM Motors)

PM Motor Poles

OLV/PM

OLV/PM

Sets the number of motor poles.

Default:

<3>

Min.: 2

Max.: 48

123

E5-05

(032D)

<1>

Motor Stator Resistance

(for PM Motors)

PM Mtr Arm Ohms

OLV/PM

OLV/PM

Set the resistance for each motor phase.

Default:

<3>

Min.: 0.000 Ω

Max.: 65.000 Ω

123

E5-06

(032E)

<1>

Motor d-Axis

Inductance (for PM

Motors)

PM Mtr d Induct

OLV/PM

OLV/PM

Sets the d-Axis inductance for the PM motor.

Default:

<3>

Min.: 0.00 mH

Max.: 300.00 mH

123

E5-07

(032F)

<1>

Motor q-Axis

Inductance (for PM

Motors)

PM Mtr q Induct

OLV/PM

OLV/PM

Sets the q-Axis inductance for the PM motor.

Default:

<3>

Min.: 0.00 mH

Max.: 600.00 mH

123

E5-09

(0331)

<1>

Motor Induction Voltage

Constant 1 (for PM

Motors)

PM Mtr Ind V 1

OLV/PM

OLV/PM

Sets the induced peak voltage per phase in units of

0.1 mV/(rad/s) [electrical angle]. Set this parameter when using

an IPM motor with variable torque.

Set E5-24 to 0 when setting this parameter.

Default:

<3>

Min.: 0.0 mV/

(rad/s)

Max.: 2000.0

mV/

(rad/s)

124

E5-24

(0353)

<1>

Motor Induction Voltage

Constant 2 (for PM

Motors)

PM Mtr Ind V 2

OLV/PM

OLV/PM

Sets the induced phase-to-phase rms voltage in units of

0.1 mV/(r/min) [mechanical angle].

Default:

<3>

Min.: 0.0 mV/

(r/min)

Max.: 6500.0

mV/

(r/min)

124

<1> Setting value is not reset to the default when drive is initialized.
<2> Default setting is determined by parameters A1-02, Control Method Selection, and o2-04, Drive Model Selection.
<3> Default setting is dependent on parameter E5-01, Motor Code Selection.
<4> Selection may vary depending on the motor code entered to E5-01.
<5> Display is in the following units:

2o0028, 2o0042, and 4o0011 to 4o0027: 0.01 A units
2o0054 to 2o0248 and 4o0034 to 4o0414: 0.1 A units