Table 5.5

gives an overview of possible fault codes. Conditions such as overvoltages can trip faults and alarms. It is important

to distinguish between faults and alarms to determine the proper corrective actions.
When the drive detects a fault, the ALM indicator LED lights, the fault code appears on the HOA keypad, and the fault contact

MA-MB-MC triggers. An alarm is present if the ALM LED blinks and the fault code on the HOA keypad flashes.

Refer to

Minor Faults and Alarms on page 191

for a list of alarm codes.

Table 5.5 Fault Displays

HOA

Keypad

Display

Name

Page

Aov

Power Supply Overvoltage

193

AUv

Power Supply Undervoltage

193

bAT

HOA Keypad Battery Low

193

bUS

Option Communication Error

193

CE

MEMOBUS/Modbus Communication Error

193

CoF

Current Offset Fault

194

CPF00 to

CPF03,

CPF07,

CPF08,

CPF11 to

CPF14,

CPF16 to

CPF24

CPF26 to

CPF35

CPF40 to

CPF45

<1> <2>

Control Circuit Error

194

CPF06

Control Circuit Error

194

CPF25

Terminal Board Not Connected

194

doH

Damping Resistor Overheat

194

EF0

Option Card External Fault

194

EF1 to EF8 External Fault

(input terminal S1 to S8)

194

Err

EEPROM Write Error

195

FAn

Fan Fault

195

FbH

Excessive PID Feedback

195

FbL

PID Feedback Loss

196

Fdv

Power Supply Frequency Fault

196

GF

Ground Fault

196

LF

Output Phase Loss

196

LF2

Current Imbalance

196

nSE

Node Setup Error

197

oC

Overcurrent

197

oFA00

<3>

Option Card Connection Error at Option Port

CN5-A

198

oFA01

Option Card Fault at Option Port CN5-A

198

oFA03 to

oFA06

Option Card Error Occurred at Option Port CN5-

A

198

oFA10,

oFA11

Option Card Error (CN5-A)

198

oFA12 to

oFA17

Option Card Connection Error

(CN5-A)

198

oFA30 to

oFA43

Comm Option Card Connection Error

(CN5-A)

198

HOA

Keypad

Display

Name

Page

oFb00

Option Card Fault at Option Port CN5-B

198

oFb01

Option Card Fault at Option Port CN5-B

198

oFb02

Option Card Fault at Option Port CN5-B

198

oFb03,

oFb11

Option Card Error Occurred at Option Port

CN5-B

198

oFb12 to

oFb17

Option Card Error Occurred at Option Port

CN5-B

198

oFC00

Option Card Connection Error at Option Port

CN5-C

199

oFC01

Option Card Fault at Option Port CN5-C

199

oFC02

Option Card Fault at Option Port CN5-C

199

oFC03,

oFC11

Option Card Error Occurred at Option Port

CN5-C

199

oFC12 to

oFC17

Option Card Error Occurred at Option Port

CN5-C

199

oFC50 to

oFC55

Option Card Error Occurred at Option Port

CN5-C

199

oH

Heatsink Overheat

199

oH1

Overheat 1 (Heatsink Overheat)

200

oH3

Motor Overheat Alarm (PTC input)

200

oH4

Motor Overheat Fault (PTC input)

200

oL1

Motor Overload

200

oL2

Drive Overload

200

oL3

Overtorque Detection 1

200

oL4

Overtorque Detection 2

201

oL5

Mechanical Weakening Detection 1

201

oPr

External Digital Operator Connection Fault

201

ov

Control Circuit Overvoltage

201

SCF

Safety Circuit Fault

201

SEr

Too Many Speed Search Restarts

201

SoH

Snubber Discharge Resistor Overheat

201

SrC

Phase Order Detection Fault

201

Srr

Internal Resistance Fault

201

STo

Pull-Out Detection

201

SvE

Zero Servo Fault

202

TdE

Time Data Error

202

TIM

Time Not Set

202

UL3

Undertorque Detection 1

202

UL5

Mechanical Weakening Detection 2

202

Uv1

<3>

Control Circuit Undervoltage Fault

203