General description, Z1000u model selection, Control mode selection – Yaskawa Z1000U User Manual
Page 25: 2 general description, Refer to table 1.1 for drive selection
1.2 General Description
u
Z1000U Model Selection
for drive selection.
Note:
The models and capacities in shown here are based on standard settings and operation conditions. Higher carrier frequencies and higher
ambient temperatures require derating.
Table 1.1 Z1000U Models
Three-Phase 200 V Class
Three-Phase 400 V Class
Drive Model
Rated Output Current (A)
Drive Model
Rated Output Current (A)
2o0028
28
4o0011
11
2o0042
42
4o0014
14
2o0054
54
4o0021
21
2o0068
68
4o0027
27
2o0081
81
4o0034
34
2o0104
104
4o0040
40
2o0130
130
4o0052
52
2o0154
154
4o0065
65
2o0192
192
4o0077
77
2o0248
248
4o0096
96
–
–
4o0124
124
–
–
4o0156
156
–
–
4o0180
180
–
–
4o0216
216
–
–
4o0240
240
–
–
4o0302
302
–
–
4o0361
361
–
–
4o0414
414
u
Control Mode Selection
gives an overview of Z1000U control modes and their various features.
Table 1.2 Control Modes and Features
Motor Type
Induction Motors
Permanent Magnet
Motors
Comments
Control Mode
V/f
OLV/PM
–
Parameter Setting
A1-02 = 0
A1-02 = 5
Default Setting is V/f control
(A1-02 =0)
Basic Description
V/f control
Open Loop Vector control for
PM motors
–
Type of Applications
Motor Type
IM
PM
–
Multi Motor
YES
–
–
Motor data unknown
YES
–
–
High Speed Accuracy
–
YES
–
Control Characteristics
Speed Control Range
1:40
1:20
May fluctuate with characteristics and
motor temperature.
Speed Accuracy
±2 to 3%
±0.2%
Speed deviation when operating at
constant speed may fluctuate with
characteristics and motor temperature.
Speed Response
3 Hz (approx.)
10 Hz
Max. frequency of a speed reference
signal that the drive can follow may
fluctuate with characteristics and motor
temperature.
Starting Torque
150% at 3 Hz
100% at
5% speed
Starting torque may fluctuate with
characteristics and motor temperature.
1.2 General Description
YASKAWA ELECTRIC TOEP C710636 10B Z1000U HVAC MATRIX Drive User Manual
25
1
Receiving