F6-32

(03CD)

PROFIBUS-DP Data

Format Selection

PB Map Select

0: PPO Type

1: Conventional

0: PPO Type

1: Conventional

Default: 0

Range: 0, 1

F6-35

(03D0)

CANopen Node ID

Selection

CO Node Address

Sets the node address.

Default: 0

Min.: 0

Max.: 126

F6-36

(03D1)

CANopen

Communication Speed

CO Baud Rate

0: Auto Detect

1: 10 kbps

2: 20 kbps

3: 50 kbps

4: 125 kbps

5: 250 kbps

6: 500 kbps

7: 800 kbps

8: 1Mbps

0: Auto-detection

1: 10 kbps

2: 20 kbps

3: 50 kbps

4: 125 kbps

5: 250 kbps

6: 500 kbps

7: 800 kbps

8: 1 Mbps

Default: 6

Range: 0 to 8

F6-40

(03D5)

CompoNet Node

Address

CN Node Adress

Reserved.

F6-41

(03D6)

CompoNet

Communication Speed

CN Baud Rate

Reserved.

F6-45

(02FB) BACnet Node Address BAC Node Address

Sets BACnet physical node address.

Default: 1

Min.: 0

Max.: 127

F6-46

(02FC) BACnet Baud Rate

BAC Baud Rate

0: 1200 bps

1: 2400 bps

2: 4800 bps

3: 9600 bps

4: 19.2 kbps

5: 38.4 kbps

6: 57.6 kbps

7: 76.8 kbps

8: 115.2 kbps

0: 1200

1: 2400

2: 4800

3: 9600

4: 19200

5: 38400

6: 57600

7: 76800

8: 115200

Default: 3

Range: 0 to 8

F6-47

(02FD) Rx to Tx Wait Time

Rx to Tx Wait T

Sets the wait time between receiving and sending for BACnet.

Default: 5 ms

Min.: 5

Max.: 65

F6-48

(02FE)

BACnet Device Object

Identifier 0

BAC Dev Obj Id 0

Sets the least significant word for BACnet.

Default: 0

Min.: 0

Max.: FFFF

F6-49

(02FF)

BACnet Device Object

Identifier 1

BAC Dev Obj Id 1

Sets the most significant word for BACnet.

Default: 0

Min.: 0

Max.: 3F

F6-50

(03C1)

DeviceNet MAC

Address

DN MAC Address

Selects the drive MAC address.

Default: 64

Min.: 0

Max.: 64

F6-51

(03C2)

DeviceNet

Communication Speed

DN Baud Rate

0: 125 kbps

1: 250 kbps

2: 500 kbps

3: Set from Network

4: Auto Detect

0: 125 kbps

1: 250 kbps

2: 500 kbps

3: Adjustable from network

4: Detect automatically

Default: 4

Range: 0 to 4

F6-52

(03C3) DeviceNet PCA Setting PCA Selection

Sets the format of the data set from the DeviceNet master to the

drive.

Default: 21

Min.: 0

Max.: 255

F6-53

(03C4) DeviceNet PPA Setting PPA Selection

Sets the format of the data set from the drive to the DeviceNet

master.

Default: 71

Min.: 0

Max.: 255

F6-54

(03C5)

DeviceNet Idle Mode

Fault Detection

DN Idle Flt Det

0: Stop

1: Ignore

0: Enabled

1: Disabled, no fault detection

Default: 0

Range: 0, 1

F6-55

(03C6)

DeviceNet Baud Rate

Monitor

DN BAUD RATE

MEM

0: 125 kbps

1: 250 kbps

2: 500 kbps

Verifies the baud rate running on the network.

0: 125 kbps

1: 250 kbps

2: 500 kbps

Default: 0

Range: 0 to 2

B.7 F: Option Settings