Three-Phase 400 V Class Drive Models 4o0096 to 4o0414

Table A.4 Power Ratings (Three-Phase 400 V Class) Continued

Item

Specification

Drive Model

4o0096 4o0124 4o0156 4o0180 4o0216 4o0240 4o0302 4o0361 4o0414

Maximum Applicable

Motor Capacity kW (HP)

<1>

55 (75)

75 (100)

90 (125) 110 (150) 132 (175) 150 (200) 185 (250) 220 (300) 260 (350)

Input/

Output

Rating

Rated Input Current (A)

<2>

87

113

142

164

197

218

275

329

377

Rated Input

Capacity (kVA)

<3>

80

103

130

150

180

200

251

300

344

Rated Output

Current (A)

<4>

<5>

96

124

156

180

216

240

302

361

414

Overload Tolerance

120% of rated output current for 60 s

(Derating may be required for applications that start and stop frequently)

Carrier Frequency

4 kHz (User adjustable up to 10 kHz. Derating may be required.)

Maximum Output Voltage (V)

Proportional to input voltage

<6>

Maximum Output

Frequency (Hz)

400 Hz (User-adjustable)

Power

Supply

Rated Voltage

Rated Frequency

Three-phase 4Uoooo and 4Poooo 380 to 500 Vac 50/60 Hz

Three-phase 4Eoooo and 4Woooo 380 to 480 Vac 50/60 Hz

Allowable Voltage Fluctuation

-15 to 10%

Allowable Frequency

Fluctuation

±3% (Frequency fluctuation rate: 1 Hz/100 ms or less)

Allowable Phase Power

Supply Voltage Unbalance

2% or less

Harmonic Current Distortion

<6>

5% or less (IEEE519 compliant)

Input Power Factor

<6>

0.98% or more (During rated operation)

<1> The motor capacity (HP) refers to an NEC 4-pole motor. The rated output current of the drive should be equal to or greater than the motor current.

Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.

<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring

connections, and power supply impedance.

<3> Rated input capacity is calculated with a power line voltage of 480 V × 1.1.
<4> The rated output current of the drive should be equal to or greater than the motor rated current.
<5> Carrier frequency is set to 4 kHz. Current derating is required to raise the carrier frequency.
<6> If one of the following specifications are needed, the maximum output voltage = [input voltage] × 0.87:

Harmonic current distortion of 5% or less
Harmonic suppression guidelines compliance
Input power factor of 0.98 or higher.

A.1 Power Ratings

YASKAWA ELECTRIC TOEP C710636 10B Z1000U HVAC MATRIX Drive User Manual

245

A

Specifications