Default keyframe – Grass Valley Kayenne K-Frame v.7.0 User Manual
Page 46

46
KAYENNE K-FRAME — User Manual
Section 3 — Setting Suite Preferences
Default Keyframe
Default Keyframe settings are applied when an empty register is recalled
and when the
CWB
(Clear Working Buffer) button is pressed in the Master
E-MEM (
EMEM Edit
,
CWB
button) of the Control Panel.
•
SPOP (Single Press)
clears the working buffer of enabled levels to Default
Keyframe, however it does not clear the source memory.
•
DPOP (Double Press)
clears the working buffer of enabled levels to Default
Keyframe and clears the source memory to the default settings for
sources selected on enabled levels.
The Default Keyframe menu is used to learn the current Control Panel state
to the system’s Default Keyframe (and to set the Default Keyframe back to
factory settings). Individual settings for each ME are stored in the Default
Keyframe, so different states can be saved for different MEs, if desired.
Note
Individual Default Keyframe settings are saved for each GV Switcher ME.