beautypg.com

Me delegation, Automatic delegation, Exchange me – Grass Valley Kayenne K-Frame v.7.0 User Manual

Page 263

background image

KAYENNE K-FRAME — User Manual

263

Control Panel Overview

ME Delegation

Any stripe can control any ME, delegation can be saved in Panel Memory.

DELG Button

The light blue

DELG

button on any Local E-MEM Module puts that module

into Panel Delegation mode and displays MEs delegated to the suite in
rows that correspond to the top to bottom Stripes on that Control Panel.
Current ME selections are high tallied with the defined ME color. Pressing
the button for an ME or PGM PST ME delegates the corresponding Stripe
to the selected ME. The same selection can be made on more than one row.

Note

Only those MEs for which physical MEs have been assigned to the suite are
displayed in Delegation mode on the Local E-MEM Module.

If the Control Panel has fewer than four Stripes, then only rows for those
Stripes present will be shown. If the Control Panel has more than four
stripes, then pressing the

Page

button on the Local E-MEM Module will

show the ME delegations for those additional Stripes.

Exchange ME

The

Exchange ME

button (see Transition Module

on page 243

) allows you to del-

egate MEs that are not assigned to a Stripe. For example on a 4.5-ME
Kayenne system with four Stripes, the fifth ME can be ‘exchanged’ with a
currently delegated ME on that Stripe by pressing the

Exchange ME

button.

The function is global for all Stripes, i.e. if ME-4 is unassigned, pressing the

Exchange ME

button on the current PGM PST Stripe assigns ME-4 to that

Stripe and PGM PST is available for exchange (delegation) on each Stripe’s

Exchange ME

button.

For Kayenne systems with more than one additional ME than available
Stripes, an ME can be preassigned to the

Exchange ME

button by holding

down the button and selecting the ME for exchange on the Local E-MEM
Module. Only one ME for exchange can be assigned at a time.

The

Exchange ME

button displays the color of the unassigned ME. For the

example above with PGM PST and ME-4, when PGM PST is red and ME-4
is purple, after ME-4 is exchanged with PGM PST the

Exchange ME

button

changes from purple to red (for each

Exchange ME

button on all Stripes in that

suite).

Automatic Delegation

With the

ADel

button toggled on in the Multi-Function Module, when an

operator activates any object on a Stripe, the Multi-Function Module will
automatically delegate to control the specific object involved. For example,
selecting a key for the next transition, automatically delegates the other
modules in that Stripe, and the Multi-Function Module to control that