beautypg.com

Control panel me partition delegation, Source selection, Me partition preview – Grass Valley Kayenne K-Frame v.7.0 User Manual

Page 344

background image

344

KAYENNE K-FRAME — User Manual

Section 8 — Advanced Operations

Control Panel ME Partition Delegation

When an ME has been split, the

Pri

and

Sec

delegation buttons on that ME

are activated.

Pri and Sec Delegation Buttons

The

Pri

and

Sec

buttons delegate the source selection buses and the Transi-

tion Module and Local E-MEM Module of that ME, to the selected parti-
tion. Pressing one of the

Pri

and

Sec

buttons deselects the other. At least one

partition is always selected on a split ME.

Delegating Both Partitions

Holding down one of the

Pri

and

Sec

buttons and pressing the other dele-

gates both partitions. When the panel is delegated to both partitions, the
E-MEM and Transition Modules control both partitions simultaneously.
Also, the button tally indicators in the Transition Module and the transition
pattern shape displayed in the ME Status display reports information for
only the Primary partition.

Source Selection

When an ME is split and its Control Panel controls are delegated to only the
Secondary partition, the alternate buses for that ME are reversed. Keyer 3
and Keyer 4 sources are selected on the keyer buses and Util 1 and Util 2
sources are selected on the background buses by default. Holding down the
delegation buttons allows source selection on the other Keyer 1, Keyer 2,
Bkgd A and Bkgd B buses. This works well for the typical situation where
an ME is split into equal partitions, with Keyer 1 and 2 assigned to the
Primary partition and Keyer 3 and 4 assigned to the Secondary partition.

If both partitions are delegated, source selection behaves the same as when
only the Primary partition has been delegated.

ME Partition Preview

Preview outputs are available for both partitions of a Split ME. The

___ MxpA

output of each bank is used for the Primary partition preview, and the

___

Mxp2

output is used for the Secondary partition preview. These preview

signals can be mapped to output connectors with the Output Assignments
menu, accessed by touching

Eng Setup

,

Outputs

.

You can preview ME primary and secondary ME partitions on switched
preview using the System Bar. Press the

Sw PVW

button and select an ME for

primary, select the ALT button (next to Sw PVW) to see the secondary.