Grass Valley Kayenne K-Frame v.7.0 User Manual
Page 246

246
KAYENNE K-FRAME — User Manual
Section 7 — Switching Basics
Next Transition Buttons
The Next Transition Element buttons are located just below the status dis-
play:
BKGD
,
K1-K6
, and
Key Prior
.
The
Next Transition Type
buttons are located below the Next Transition
Element buttons:
Mix
,
Wipe 1
,
Wipe 2
, and
User 1-User 6
(radio buttons).
Selecting one turns the others off if a next transition element button is not
held down.
Cut and Auto Buttons
The
Cut
and
Auto
buttons are located at the bottom, middle of the Transition
Module.
•
Cut
—Executes a cut on the buses selected as being in the set of next tran-
sition elements.
•
Auto
—causes the selected next transition type to be executed with a
Next Transition Duration.
A press and release of a Next Transition Element button high tallies the
button and low tallies the others.
To multi-select next transition element buttons:
•
Press more than one button at a time or,
•
Press and hold down any of the eight transition element buttons and
then select one or more of the remaining buttons.
The rule is that while any next transition button is held down, other next
transition buttons can be added or removed from the next transition by tog-
gling that button.
Additional Buttons
•
Trans PVW
(Transition Preview)—When a transition is performed in this
mode, it occurs only on the LAP output. At completion of the transition,
the Transition Preview is auto-canceled.
Pressing the
Trans PVW
button causes the button to flash. Both the PGM
and LAP outputs show the current PGM out stack.
•
Trig
(Trigger)—Inactive
•
PST Black
(Preset Black)—Pressing the
PST Black
button, then pressing the
Cut
button,
Auto
button, or using the lever arm, will delegate the first
transition using Mix or Wipe to black.