beautypg.com

Multiple suites and source names, Source name display hierarchy – Grass Valley Kayenne K-Frame v.7.0 User Manual

Page 41

background image

KAYENNE K-FRAME — User Manual

41

About Source Patching

operator names from the OLED names to show C1, C2, and C3 in larger
characters. These alternative names are entered in the Source Patch menu.

The Source Patch menu (

Figure 19

) has three editable columns for defining

up to three alternative names:

A

Panel Name

is limited to four characters, to fit the space available on the

Control Panel’s Transition Area. This name is only displayed on the Control
Panel.

An

OLED Name

appears only on the Source Name Displays on the Control

Panel. Up to eight characters are displayed.

A

Menu Name

is limited to eight characters, and appears on all the GV

Switcher menu application screens except Engineering Setup menus,
which always display engineering IDs or names.

Multiple Suites and Source Names

Different sets of these alternative source names are defined for each GV
Switcher suite. Ensure the GV Switcher Menu Application you are using is
logged into the correct suite (

Eng Setup

,

Eng Logon

). The same set of engi-

neering names will be used by both GV Switcher suites, however.

Source Name Display Hierarchy

If a source’s engineering name is left blank, the Eng ID number will be
used. If no alternative names are defined for that source, then that Eng ID
number will appear on all the GV Switcher system displays.

If an engineering name has been entered (see the GV Switcher Installation
& Service Manual
for your model) then the engineering name will be dis-
played on all the GV Switcher system displays, including menus. Engi-
neering names will be truncated to the character limits of the display,
starting with the first character.

For alternative names entered in the User Setups, Suite Prefs, Source Patch
menu (

Figure 19

), the following rules apply:

For the three editable columns:

Panel Name

,

OLED Name

, and

Menu Name

, if any

of the three are left blank for that source, the first name to the left appears
in that display on the system (if all three are left blank, the name in the Eng.
Source Column is displayed). For example, if an alternative name is entered
in the OLED Name column for a source and the other two columns remain
blank, the Menu Name takes the OLED Name (OLED Name being first to
the left of the Menu Name) but the Panel Name takes the Eng. Source
column’s name (first name to its left). If names are entered in all three alter-
native name columns, each area of the system displays the name entered in
each column of the Source Patch menu (

Figure 19

).