403
Config Menu
Figure 326. Config E-Box Input - General
To configure the source names, select the parameter from the scroll list.
Then press Modify to change the parameters.
•
4 char ID / 8 chr ID:
The Name of a source is displayed on the Control panel, and is limited
to four characters. The Long Name of a source appears in configuration
menus, and can be eight characters long. Touching Modify
brings up a
keypad to enter that name for the selected source.
•
Coupled:
Touching the Modify
button calls a subdialog. In this menu the Key to be
coupled to the selected Fill source can be selected.
•
Real Input: Touching Modify on one of the 16 Virtual Inputs brings up a
subdialog to select the real input.
•
Attached Machine:
You can attach machines to an input to use it for automatic delegation
of the machine control sections in the control panel System bar.
Touching the Modify button calls a subdialog where you can select your
machine.