110

Kayenne XL Package — User Manual

Section 3 — Control Panel

The transition type can be changed when the M/E has reached its first
preset black stage, allowing for example a wipe to and a mix from preset
black. While in preset black, the key ON indicators report the states the
keys will have when the second transition command completes. The keys
involved can be changed at this time, if desired. The source on the PST bus
can also be changed while in the preset black stage.

A preset black transition can be canceled by pressing the Preset Black button
a second time. If cancelled while at the preset black stage, the system will
switch back the original signal. Pressing a source button on the PGM bus
will also cancel a preset black transition. The source pressed on the A bus
will immediately be placed on air without any keys, even if the next transi-
tion had specified key changes.

Transition Preview

The transition preview feature enable a main transition to be previewed
without affecting the program output. A transition preview cannot be per-
formed if the Transition Lever Arm or main transition is off limit, if an auto
transition is in progress, or when Preset Black has been selected.

Pressing Trans Pvw routes the main transition video to preview output and
disables program transitions on that M/E, leaving the existing program
output unchanged. Pressing Auto Trans or moving the Transition Lever Arm
with Trans Pvw

active will show the transition only on preview, allowing the

setting of wipe parameters or adjusting auto transition times before actu-
ally performing that transition. Transition preview overrides whatever
preview mode is currently selected.

Transition preview may be canceled at any time by pressing the lit Trans
Pvw
button. If an auto transition preview is in progress, it will be aborted.
If the transition lever arm was used for the transition preview, canceling the
preview part way through will cause the lever arm to resynchronize by
recalculating the resting lever arm way to complete the transition in the
direction of the arrow. Moving the lever arm in the opposite direction
enable you to resynchronize the arm to an end position without affecting
the output signal.

Transition Rates

Auto transition rates are set using the Trans Rate button at Transition panel
and keypad located at the Local EMEM panel.

When the Trans Rate button is pressed, the Auto button in the Main Transi-
tion subpanel and the six Key1 - 6 Mix buttons will flash and the display in
the local EMEM subpanel prompts ”select component”. A flashing button
indicates the status of this component unselected. Select the components
where you would like to change the Transition Duration, enter the new