4–46

Chapter 4: Functional Description

CPU Interface

CPRI MegaCore Function

December 2013

Altera Corporation

User Guide

Control Word Order

The entries in the control receive and control transmit tables match the organization of
control words in subchannels from the CPRI specification.

Figure 4–25

shows this

word order. The figure is Figure 15 of the CPRI V5.0 Specification.

Figure 4–25

illustrates how the 256 control words in the hyperframe are organized as

64 subchannels of four control words each. The figure illustrates why the index X of a
control word is Ns + 64 × Xs, where Ns is the subchannel index and Xs is the index of
the control word within the subchannel.

Control Word Transmission Example

To write to the vendor-specific portion of the control word in a transmitted
hyperframe, perform the following steps:

1. Identify the indices for the vendor-specific portion of the transmit control table,

using the formula X = Ns + 64 × Xs.

In the example, Ns = 16 and Xs = 0,1,2, and 3. Therefore, the indices to be written
are 16, 80, 144, and 208.

2. For each value X in 16, 80, 144, and 208, perform the sequence of steps listed in

“Writing the Outgoing Control Words” on page 4–44

.

Figure 4–25. Illustration of Subchannels in a Hyperframe

Xs == 0

1

2

3

Ns == 0

0: K28.5

Synchronization and Timing

1

1: HDLC link

65: HDLC

129: HDLC

193: HDLC

2

2: L1 In-band

66: L1 in-band

130: L1 in-band

194: P (20 = 0x14)

3

3: Reserved

67: Reserved

4

4: Ctrl_AxC

...

...

...

...

7

7: Ctrl_AxC

71: Ctrl_AxC

135: Ctrl_AxC

199: Ctrl_AxC

...

14

14: Reserved

15

15: Reserved

79: Reserved

143: Reserved

207: Reserved

16

Vendor-specific

...

19

20

Pointer P --->

20: Ethernet

...

62

62

126

190

254

63

63

127

191

255