Configuring MicroLogix 1100/1200/1500 Controllers 3-67

The data is retrieved as an ASCII string with the following format:

st

Data><2

nd

Data>

Data>

where:

= mm/dd/yyyy - ASCII characters (date is optional)

= User Defined Separator (TAB, COMMA, or SPACE)

= ASCII decimal representation of the value of the data

= record string is null terminated

If the Real Time Clock module is not present in the controller,
is formatted as 00/00/0000, and

The Communications Device determines the number of sets of
data that have been recorded but not retrieved.

The controller performs a the data integrity check for each
record. If the data integrity check is invalid, a failure response is
sent to the Communications Device. The data set is deleted as
soon as the failure response is queued for transmission.

Accessing the Retrieval File

You can use a dedicated retrieval tool or create your own application.

Retrieval Tools

There are a number of retrieval tools designed for use with Palm OS,
Windows

®

CE, Windows 9x, and Windows NT

®

. You can download

these free tools from our web site. Visit
http://www.ab.com/micrologix.

TIP

For easy use with Microsoft Excel, use the TAB
character as the separator character.