Appendix E. Log Files
TABLE E-1. Transaction Log Messages
Code
Message Text
Message Parameters
Message Meaning
User Response to
Message
44
Terminal
emulation
transaction
complete
Terminal emulation
response message has
been received from
the datalogger.
45
Terminal
emulation
transaction
failed
The expected
terminal emulation
response from the
datalogger was not
received.
46
Set variable
started
The message to set an
input location, flag or
port has been sent to
the datalogger.
47
Set variable
complete
The datalogger has
acknowledged the set
of an input location,
flag or port.
48
Set variable
failed
The datalogger failed
to acknowledge the
set variable message.
49
Table resized
The size of the table
storage area in the
data cache has been
changed.
If the table is made
smaller the oldest data
will be lost.
50
Program file
send start
The server is sending
a program to the
datalogger. The
actual program
segments will appear
as BMP1 message
type 4.
51
Program file
send status
The datalogger has
received the program
segment.
52
Program file
send complete
The datalogger has
compiled the
program.
53
Program file
send failed
The datalogger did
not acknowledge the
receipt of the
program, the program
did not compile, or
communications
failed with the
datalogger.
If the program did not
compile check the error
messages. Otherwise,
check communications
with the datalogger by
trying to check the
clock. If that fails,
follow the steps for
message 14.